| MODEL NO. |
12 Volt System 24 Volt System 48 Volt System
|
PM-1500SSL-12X(1) PM-1500SSL-24X PM-1500SSL-48X
|
PM-3000SSL-12X(1) PM-3000SSL-24X PM-3000SSL-48X
|
| GENERAL |
| Ventilation |
Forced cooling
|
Forced cooling
|
Temperature
|
Operation Storage |
-20°C ~ +70°C -25°C ~ +80°C
|
-20°C ~ +70°C -25°C ~ +80°C
|
| Protection |
|
|
|
a. Output short circuit |
∨
|
∨
|
|
b. Over load |
∨
|
∨
|
|
c. Battery voltage too high |
∨
|
∨
|
|
d. Battery voltage too low |
∨
|
∨
|
|
e. DC voltage ripple too high |
∨
|
∨
|
|
f. Temperature Sensor |
|
|
|
Transformer |
∨(105°C)
|
∨(105°C)
|
|
Electronic & Powerstage |
∨(70°C)
|
∨(70°C)
|
|
BTS-3 |
∨(50°C)
|
∨(50°C)
|
| Humidity |
0~95% (non condensing)
|
0~95% (non condensing)
|
| Power control Function |
∨
|
∨
|
| Power assist Function |
∨
|
∨
|
| Uninterrupted AC power |
∨(less than 10 msec)
|
∨(less than 10 msec)
|
| Adaptive 4-stage charge |
∨
|
∨
|
| Two output to charge 2 battery banks |
∨
|
∨
|
| Auxiliary Relay |
X 3
|
X 3
|
| Battery voltage sensor |
∨
|
∨
|
| Battery Temperature sensor (BTS-3) |
∨
|
∨
|
| Remote control port |
∨
|
∨
|
| INVERTER |
| Input Voltage Range (VDC) |
9.5~16V / 19~32V / 38~64V
|
| Output Voltage (VAC) |
185~240 VAC / 90~120 VAC
|
| Output Frequency |
50Hz / 60Hz ± 0.1%
|
| Output Waveform |
Pure sinewave
|
| Output Voltage THD |
< 5%
|
| Power Factor (All Loads) |
∨
|
| No linger load, crest factor |
3 : 1
|
|
Cont. Power Output (W) Under 70°C (cosθ=1.0)
|
1500W (No derate)
|
3000W (No derate)
|
Cont. Power Output (W) Over 70°C (cosθ=1.0) |
0W (Shutdown)
|
0W (Shutdown)
|
| Maximum Power (W) |
3000W
|
6000W
|
| Maximum Efficiency (%) |
82/84/85
|
84/86/89
|
| Zero-load Power (W) |
12W
|
18W
|
| CHARGER |
| Input Voltage Range (VAC) |
200~250 VAC / 100~125 VAC
|
| Input Frequency |
45-55Hz / 55-65 Hz
|
| Power Factor |
1
|
| Charge Characteristic |
4-stage adaptive / Bulk-Absorption-Float-Equalize
|
| Maximum DC Voltage Ripple (Vrms) |
< 1.25 V
|
| Charge Current House Battery (A) |
70A/40A/20A
|
140A/70A/40A
|
| Charge Current Starter Battery (A) |
4A
|
| Absorption Voltage Default (VDC) |
14.4V / 28.8V / 57.6V
|
| Float voltage Default (VDC) |
13.8V / 27.6V / 55.2V
|
| Equalize Voltage default (VDC) |
13.2V / 26.4V / 52.8V
|
| Output Charge Voltage (min ~ max) |
8V~16V / 11V~32V / 22V~64V
|
| Battery Temperature sensor |
BTS-3
|
| SOLAR CHARGE |
| System voltage ratings |
12, 24, 48 Vdc
|
| Current ratings-Battery Charge Control |
40A
|
| Accuracy |
12/24V:≤0.1 % ± 50 mV 48V:≤0.1 % ± 100 mV
|
| Min. voltage to operate |
9V
|
| Max. solar array Voc |
140V
|
| Max. operating voltage |
68V
|
| Total current consumption |
While operating -25mA, at idle -3mA
|
| High temp shutdown |
90°C disconnect solar 70°C reconnect solar
|
| Transient surge protection |
|
pulse power rating |
4500 watts
|
|
Response |
< 5 nanosec
|
| ENVIRONMENTAL |
| Ambient temperature |
-40 to +45°C
|
| Storage temperature |
-55 to +85°C
|
| Humidity |
100% (NC)
|
| AC INPUT SWITCH |
| AC IN Terminal Circuit Breaker |
30A (110V) /15A (220V)
|
60A (110V) /30A (220V)
|
| Switch-over Time |
|
|
a. inverter to AC input |
0 msec.
|
|
b. AC input to inverter |
0 msec.
|
| Detection Time AC Input Fault |
4 ~10 msec.
|
| Trip Level AC Input to Inverter |
90 VAC / 180 VAC
|
| Trip Level Inverter to AC Input |
94 VAC / 187 VAC
|
| Min.~ Max. Frequency Range |
45-55 Hz / 55-65 Hz
|
| MECHANICAL |
| Cabinet / Protecting Class |
Aluminum / IP20
|
| Dimension (H X W X D) |
Wall: 298 x 256 x 368 Table: 189 x 285 x 494 (mm)
|
Wall: 355 x 256 x 368 Table: 189 x 285 x 708 (mm)
|
| Weight (kgs) |
30 kgs
|
35 kgs
|